Brand Name : KAIXIANG
Model Number : 1440 KW
Certification : ISO9001
Place of Origin : HEBEI CHINA
MOQ : ONE SET
Price : negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 20 SETS ONE MONTH
Delivery Time : ONE MONTH AFTER GET DEPOSIT
Packaging Details : WOODEN CASE
Resistive load : 1440 KW
Load Tolerance : ±3%
Control Power : 380VAC/50Hz,
Load Step : F1,2,2,5,10,20,20,50,100,100,200,200,200,200,200,200, 200,200,200,200,200,200,200,200,200,200,200,200,200,200,200kw,
Altitude : ≤2500 meter
Rating Voltage/Frequency : 504V 60HZ
Ocean Engineering Dummy Electrical Load Bank 1440KW Generator Test
Product Description
The system consists of 1 sets of 1440kw load bank. The system is made up of two parts of measurement and control and load, mainly including the dry type ac load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.
Technical Parameter
| Rating Voltage/Frequency | 480VAC/60Hz, 3 phase 4 wire, line | 
| Max Rated voltage | 504V 60HZ | 
| Rated power | 1440kW | 
| Load Step | A Phase 10,20,20,,20,50kw B phase 10,20,20,,20,50kw C phase 10,20,20,,20,50kw | 
| PF(Power Factor) | 1 | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | 380VAC/50Hz, 3 phase 4 wire, | 
| Wire Connection | Load power supply input——Copper bar (star coupling) Control power supply input——Connector-bar | 
| Insulation | F | 
| Protection Grade | IP21 | 
| communication interface | RS485,RS232 | 
| Casing Dimensions and Cooling | about 2800*1900*2400mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling | 
| Weight | About 1800kgs/set | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Casing Color | Grey(RAL7035) | 
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Altitude | ≤2500 meter | 
| Atmospheric Pressure | 86~106kPa | 
| Contactor | Schneider | 
| Fuse | DELIXI | 
| MCU | INFINEON | 
| Data processing software | Kaixiang(self-developed) | 
| Alloy Resistance | Kaixiang(self-developed) | 
Product Advantage
1. Manual load: input power and power factor.
2. Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.
3. Parallel testing: when several load banks parallel working, parameters of each load bank can be displayed and recorded, so do the final parameters of paralleling working.
4. Real-time parameter: Current, voltage, power, power factor, frequency, time, etc could be displayed by software.
Application
Load banks may be installed in a diesel powered generator set to apply the additional load required to ensure the engine fully consumes the fuel in the combustion process. If a diesel engine is not operated under adequate load, unconsumed fuel will collect in the engine’s exhaust stack and form an oily coating.

|   | 
| Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator Images | 
 Automatic Electrical Load Bank Intelligent Orange With Manual Control Panel
                                                                                    
                        
                        
                        
                                                            Automatic Electrical Load Bank Intelligent Orange With Manual Control Panel
                                                    
                        
                     Automatic 2000 KW Electrical Load Bank , Continuous Working AC Load Bank
                                                                                    
                        
                        
                        
                                                            Automatic 2000 KW Electrical Load Bank , Continuous Working AC Load Bank
                                                    
                        
                     Large Gray 3 Phase Load Bank 2100 KW Line Voltage 400 V With Hydro Generators
                                                                                    
                        
                        
                        
                                                            Large Gray 3 Phase Load Bank 2100 KW Line Voltage 400 V With Hydro Generators
                                                    
                        
                     Over Heat Protection Variable Resistive Load Bank With Phase Voltage 230 V
                                                                                    
                        
                        
                        
                                                            Over Heat Protection Variable Resistive Load Bank With Phase Voltage 230 V
                                                    
                        
                     2400 KW Electrical Load Bank , Resistive Load Bank For Storage Battery Systems
                                                                                    
                        
                        
                        
                                                            2400 KW Electrical Load Bank , Resistive Load Bank For Storage Battery Systems
                                                    
                        
                     2500 KW Electrical Load Bank Over Heat Protection With Fan Cooling System
                                                                                    
                        
                        
                        
                                                            2500 KW Electrical Load Bank Over Heat Protection With Fan Cooling System
                                                    
                        
                     Safety Monitoring Variable Resistive Load Bank Continuous Working For Generator
                                                                                    
                        
                        
                        
                                                            Safety Monitoring Variable Resistive Load Bank Continuous Working For Generator
                                                    
                        
                     4510 KW High Capacity Electrical Load Bank , 60 HZ Resistive Load Bank
                                                                                    
                        
                        
                        
                                                            4510 KW High Capacity Electrical Load Bank , 60 HZ Resistive Load Bank
                                                    
                        
                     Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator
                                                                                    
                        
                        
                        
                                                            Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator
                                                    
                        
                     Ocean Engineering Dummy Load Bank Automatic 400 V With Alloy Resistance
                                                                                    
                        
                        
                        
                                                            Ocean Engineering Dummy Load Bank Automatic 400 V With Alloy Resistance